National Repository of Grey Literature 39 records found  1 - 10nextend  jump to record: Search took 0.01 seconds. 
Workstation with termo camera
Zeman, Martin ; Horák, Karel (referee) ; Richter, Miloslav (advisor)
This thesis contains an overview of physical principles concerning thermography and infra-red sensing, and a specification of a measuring instrument in a measurement system. Next, there are some particular examples of IR sensing applications. In the second part there is a thermal camera market research including individual manufacturers and models with their attributes and prices. There is a closer view of the thermal camera used for this thesis (Guide EasIR-4). In the end of the thesis there are some drafts of computer vision subject tasks (or practices), including workplace designs and solutions, and three task suggestions for bachelor or diploma theses including solution verifications.
IR camera data processing
Malík, Dalibor ; Petyovský, Petr (referee) ; Richter, Miloslav (advisor)
The aim of this master’s thesis is to give information about the thermo camera measurement with error minimization. The basic concepts of thermography are explained with an implementation of postprocesing technique which uses graphically modified thermogram back projected to the scene. This is closely related to the scene design, calibration of thermal camera with projector, image rectification, thermogram processing with highlighting of interesting information and implementation of control elements as the user interface. The results obtained are analyzed and re-evaluated.
Emisivity and its Impact on the Heat Conductivity
Gančev, Jan ; Hejátková, Edita (referee) ; Szendiuch, Ivan (advisor)
This work deals with the issue of emissivity and its impact on the heat dissipation.The first part describes the basics of thermal management, the issue of emissivity and its measurement. In the second, experimental part, are dedicated the emissivity values of examined specimens. These values are then used as initial conditions for the thermal simulation. In the last part are compared the measured results and the simulated results and is evaluated the impact of emissivity for the heat dissipation.
Utilization of thermal systems at power electrical engineering
Strnad, Karel ; Janda, Marcel (referee) ; Kuchyňková, Hana (advisor)
The main theme of the master's thesis is using of thermal camera to measure temperatures in electrical engineering. First are mentioned the physical principles of heat transfer. Then the thesis deals with methods of determining the correct emissivity of the measured object and in the next point with sensors designed for sensing infrared radiation, there is also part dedicated to evaluation software Report Sat Standard, which was used to evaluate the pictures taken with thermal camera SAT-HY 6800. Next part of this work is the measurement of the DC and EC motor with help of thermocamera, which took place in the electric company ATAS Nachod. Attachment to this master's thesis there is animation of EC motor created in Autodesk Inventor.
QFN Packages Soldering and Technology Procedures
Jakub, Miroslav ; Brno, Petr Martinec, HONEYWELL (referee) ; Starý, Jiří (advisor)
This master´s thesis deals with QFN packages soldering and technology procedures optimization. The aim of theoretical part is description of QFN packages, their assembly and reflow soldering on PCB in HONEYWELL. The aim of the practical part is to propose a method of measuring temperature and optimizing the thermal profiles of selected PCB with QFN packages by using convection (HONEYWELL) and infrared (BUT) reflow ovens. Comparison and evaluation of thermal profiles for 3 production PCBś with QFN packages using solder paste AIM NC257-2 were realised. The main part of master´s thesis are appearance evaluation of solder joints, preparing microsection and measuring intermetallic layers thickness by using the optical and the scanning electron microscopes, analysation and study of QFN defects created during soldering proces. These tests were performed with 2 production PCB´s. Optimization of SPI and soldering technology procedures where were analyzed QFN packages were processed on one type of PCB. Interesting part of this diplomma thesis is creating of the 3D heat transfer model of QFN package during the reflow soldering in SolidWorks.
Camera for biological applications
Jurák, Petr ; Slovák, Jiří (referee) ; Kubíček, Michal (advisor)
This diploma thesis is focused on the design of IP blocks for thermal camera. This termal camera is intended for plant research. The main part of the thermal camera is an infrared detector that detects a frequency in the range of 8 – 14 m. The analogue signal obtained is modified and subsequently digitized. The detector also includes a Peltier device which is designed for both detector cooling and heating, and is controlled by an external signal. The MicroZed development board implements IP blocks. The thermal camera is designed to be controlled from the MicroZed board. Device analysis is first described from the theoretical part to the design of IP blocks.
Thermal camera for biological applications
Macura, Jáchym ; Král, Jan (referee) ; Kubíček, Michal (advisor)
Diplomová práce se zabývá návrhem termální kamery pro biologické aplikace. V první části je popsáné infračervené záření, také známé jako thermální záření. Pokračuje popisem emisivity objektů, která hraje důležitou roli při stanovení teploty snímaného objektu. Dále je v první kapitole uveden přehled typů termálních detektorů a jejich základní vlastnosti. Druhá kapitola stručně seznamuje se zákládními hardwarovými komponenty vyvíjené kamery. V poslední kapitole je popsán celý proces vývoje softwaru. Ten zahrnuje vývoj IP jader, kernel modulů a C++ knihoven.
Non-contact temperature measurement
Sládek, Vojtěch ; Minář, Petr (referee) ; Hermanský, Dominik (advisor)
The aim of the thesis was the study of non-contact temperature measurement and the use of this measurement in the field of production machines. The first part of thesis includes concepts and definitions that are necessary for familiarization with the issue. In the second, practical part, contact and non-contact measurements were compared in two experiments. In the first one the machine frame was measured, on which the thermal load was simulated, the emission was determined, which was compared with emissivity from the tables. In the second experiment, the temperature gradient of the ball screw was measured during the ball screw operation and was determined emissivity, which was again compared with the table values. The conclusion of the thesis summarizes advantages and disadvantages of non-contact measurements that have been verified in practice.
Application of thermal camera for analysis of heat
Palička, David ; Pokorný, Jan (referee) ; Lízal, František (advisor)
Within this bachelor degree thesis I have focused on the thermal losses from storage tanks serving as asphalt binders. I have used the theory of non-contact temperature measurements using a thermovision camera. In the first part of this document I deal with the history, theory and some basic principles of non-contact temperature measurements. In the second part I am examining the thermovision camera settings. The third part considers the function of the asphalt mixture production plant itself, as well as the function of storage tanks. In the last part of this thesis I analyze the results of the measurements. The goal of this analysis is to compare results of thermal losses from storage tanks heated with thermal oil, and storage tanks heated with an electrical thermocouple.
Thermal Imaging System for Measuring Body Temperature
Mysza, Róbert ; Kolář, Dušan (referee) ; Goldmann, Tomáš (advisor)
The COVID-19 pandemic brought increased need for measuring human temperature. This thesis deals with solution of using low-cost thermal camera module FLIR Lepton 3.5 for measuring human forehead temperature and examines the real usability of this in terms of an accuracy. In the beginning, I describe various methods of measuring temperature and factors, which can influence the measurement. Subsequently, I examine various factors influencing human body and surface temperature. As of result of thesis is full design and implementation of thermal image system for temperature measurement, which I tested in different environmental conditions and compared its the precision against medical contactless infrared thermometer.

National Repository of Grey Literature : 39 records found   1 - 10nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.